2. Installation Environment
20
Temperature and Humidity
Maintain the specied temperature and humidity even when the machine is not in use. Temperatures that are too high may
degrade the ink and cause malfunction. Temperatures that are too low may cause the ink to freeze and damage the heads.
During operation: Temperature 20 to 32°C (68 to 90°F), relative humidity 35 to 80% (no condensation)
During non-operation: Temperature 5 to 40°C (41 to 104°F), relative humidity 20 to 80% (no condensation)
Installation Space
The space shown in the gure is required in order to use this machine.
650 mm
(26 in.)
3,300 mm (130 in.) (54-inch model)
2,700 mm (107 in.) (30-inch model)
2,400 mm (95 in.)