  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
8
Troubleshooting
When synchronizing using a MIDI
sequencer as the master, the VS-1824
does not respond to the sequencer
messages
The MIDI cable is not connected correctly.
The MIDI cable is broken.
You are trying to synchronize using the MIDI clock.
The VS-1824 cannot be run in slave mode using a
method other than MTC.
The EXT indicator is off (“Sync Source” is set to “INT”).
The two devices are not set to the same type of MTC
(during MTC synchronization).
The settings of the MIDI sequencer are not correct.
The VS-1824 is not in playback standby mode (with the
PLAY indicator blinking).
MTC reception is in poor condition.
Setting the Sync Error Level to “5” or higher may
improve conditions.
With a video device as the master, the
VS-1824 does not respond
The cable connected to the L-connector, the SYSTEM E
connector or the MIDI cable is not properly connected.
The MIDI cable is broken.
The EXT indicator is off (“Sync Source” is set to “INT”).
“SysEX.Rx.” (System Exclusive Receive Switch) is not set
to “On.”
“MMC” (MMC mode) is not set to “SLAVE.”
The MTC frame rate of the video device differs from that
of the SI-80SP (Roland Video MIDI Sync Interface), or the
video and the VS-1824 are not set to the same type of
MTC.
MTC reception is in poor condition.
Setting the Sync Error Level to “5” or higher may
improve conditions.
Other problems
Data on the disk drive was not saved
properly
The VS-1824’s power was turned off without performing
the shutdown process.
The power was turned off while the disk drive was
operating.
•A strong shock was applied to the disk drive.
The disk drive or SCSI cable was connected or
disconnected while the power was still turned on.
Reinitialize the disk drive (and also execute physical
formatting) (Owner’s Manual p. 229). Also, we
recommend that you execute Surface Scan as well
(Owner’s Manual p. 231).