Roland GT-6B User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
MIDI Implementation
4. PARAMETER ADDRESS MAP
The address and size are displayed under 7-bit hexadecimal notation.
Address MSB LSB
Binary 0aaa aaaa 0bbb bbbb 0ccc cccc 0ddd dddd
7-bit Hexadecima AA BB CC DD
Size MSB LSB
Binary 0sss ssss 0ttt tttt 0uuu uuuu 0vvv vvvv
7-bit Hexadecimal SS TT UU VV
Address Block Map
--------------------------------------------------------------------------------
Address Block Sub Block Note
00 00 00 00 +----------------------------------------+
| TUNER | ......Bulk
+----------------------------------------+ *Refer to Table TUNER
02 00 00 00 +-------------------+ +------------------+
| UTILITY | | GLOBAL | ......Bulk
| | +------------------+ *Refer to Table GLOBAL
02 01 00 00 | | +------------------+
| | | SYSTEM | ......Bulk
| | +------------------+ *Refer to Table SYSTEM
02 02 00 00 | | +------------------+
| | | MIDI | ......Bulk
+-------------------+ +------------------+ *Refer to Table MIDI
02 04 00 00 +----------------------------------------+
| HARMONIST SCALE | ......Bulk
+----------------------------------------+ *Refer to Table HARMONIST
02 05 00 00 +----------------------------------------+
| AUTO SLAP PHRASE | ......Bulk
+----------------------------------------+ *Refer to Table AUTO SLAP
02 07 00 00 +----------------------------------------+
| OVERDRIVE/DISTORTION Customaize | ......Bulk
+----------------------------------------+ *Refer to Table OD/DS
02 08 00 00 +----------------------------------------+
| WAH Customaize | ......Bulk
+----------------------------------------+ *Refer to Table WAH
04 00 00 00 +-------------------+ +------------------+
| Quick Setting | | ROM Area | ......Bulk(Read Only)
| | +------------------+ *Refer to Table Quick Fx
05 00 00 00 | | +------------------+
| | | ROM Area(Name) | ......Bulk(Read Only)
+-------------------+ +------------------+ *Refer to Table Quick Fx
06 00 00 00 +-------------------+ +------------------+
| User Patch | | Patch Bank U1-1 | ......Bulk
| | +------------------+ *Refer to Table Patch
06 01 00 00 | | +------------------+
| | | Patch Bank U1-2 |
| | +------------------+
: | | :
: | | :
06 27 00 00 | | +------------------+
| | | Patch Bank U0-4 |
| | +------------------+
06 28 00 00 | | +------------------+
| | | Patch Bank u1-1 |
| | +------------------+
: | | :
: | | :
06 4F 00 00 | | +------------------+
| | | Patch Bank u0-4 |
+-------------------+ +------------------+
08 00 00 00 +-------------------+ +------------------+
| ROM Patch | | Patch Bank P1-1 | ......Bulk(Read Only)
| | +------------------+ *Refer to Table Patch
08 01 00 00 | | +------------------+
| | | Patch Bank P1-2 |
| | +------------------+
: | | :
: | | :
08 27 00 00 | | +------------------+
| | | Patch Bank P0-4 |
+-------------------+ +------------------+
0A 00 00 00 +----------------------------------------+
| Temporary Buffer | ......Bulk
+----------------------------------------+ *Refer to Table Patch
0B 00 00 00 +----------------------------------------+
| Temporary Buffer | ..Individual(Write Only)
+----------------------------------------+ *Refer to Table Patch
* The GT-6B can use two methods of communication; Individual Parameter and Bulk Dump.
* Bulk data can be received when the Bulk Load Ready function is accessed in Utility mode.
* Although individual data can be received at any time, be sure to appropriately describe the value for one parameter in one packet [F0...F7].
* When a data request is to be received, use Bulk Load Ready in the utility.
* Do not use an address appended with “#” as the first address.
* Parameters for which Size is 2 or higher should not be separated; make sure these are sent in the same packet.
Page view 2
1 2 3 4 5 6 7 8 ... 25 26

Comments to this Manuals

No comments