Roland MC-808 Specifications Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
25
Mar.2006 MC-808
Updating the system
Before you execute the system update, please use the User Backup function to
save the contents of internal user memory to a CompactFlash card. (p.??? “User
Backup”)
If you replace the main board, you’ll need to specify the export region after
updating the system.
Required items
The MC-808 itself
Update CD-ROM (#17041873)
Two CompactFlash cards (1 GB or less; one for the update, one for user
data backup)
Computer (with CD-ROM drive and a card reader/writer that supports
CompactFlash, OS: Windows Me/2000/XP)
Do not use a Mac under any circumstances.
Update procedure
1. Start up your computer, and insert the CompactFlash card and the
Update Data For Service CD-ROM into the computer.
2. Using your computer, format the CompactFlash card.
3. From the Update Data For Service CD-ROM, copy the entire “ROLAND”
folder into the CompactFlash card.
4. Using the Safely Remove Hardware icon shown in the taskbar at the
lower right of your computer screen, cancel the connection between your
computer and the card reader/writer.
5. Remove the CompactFlash card from your card reader/writer.
6. With the MC-808 powered-off, insert the above card into the MC-808.
7. When you power-on the MC-808, the update will begin automatically.
* Once the update begins, it will take approximately five to ten minutes for the
process to be completed.
8. When the LCD display indicates “- Completed.” the update has been
completed.
fig.13-completed.eps_68
9. This completes the update procedure. Power-off the MC-808, and remove
the CompactFlash card from the MC-808.
10. Power-on the MC-808, and execute Test mode.
If the update fails
Turn off the power, and then turn it on again to execute the update again.
If the update fails again, it is probably that the update card was not
created correctly. Please repeat the process of creating the update card,
and try the update again.
If you are still unsuccessful, replace the main board.
If you replace the main board
If you execute the update after replacing the main board, you’ll need to set the
export region correctly.
To verify or change the export region, proceed as follows.
Changing the export region
1. Power-on the MC-808.
2. Press [SYSTEM] to enter System mode.
3. Hold down [SHIFT] and press keyboard pad [14].
4. Use [CURSOR < >] to select [Version].
5. Hold down [SCALE MEASURE] and press the part buttons in the order
of [1], [7], [8], [9].
6. You will enter the Startup page. Hold down [SHIFT] and press part
button [14]. The following indication will appear in the LCD display.
fig.14-factory-reset1.eps_68
7. Turn the [VALUE dial] or use [INC][DEC] to select either “100,” “117,” or
“230/240” as the appropriate voltage for the export region.
8. Press [ENTER], and a factory reset will be executed.
* If you don’t want to execute a factory reset, power-off the MC-808.
fig.15-factory-reset2.eps_68
9. When the factory reset is completed, the LCD display will show the
following.
fig.16-power-off.eps_68
10. Turn the MC-808 power off, and then on again.
Checking the export region
The order of pattern USER 003 and following will differ depending on the
export region.
After you power-on the MC-808, press [CURSOR >] twice to select the USER
003 pattern, and note the export region indicated by the pattern name that
appears, as listed below.
“100”: Get It
“117”: My Only Tap
“230/240”: Melodic Trance 2
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 45 46

Comments to this Manuals

No comments