Use MIDI functionality
* The setting will be cancelled if you press another button instead of the
[ENTER]
button.
OMNI
If you turn the Omni setting ON, all messages will be transmitted on the current channel
regardless of the channel that is specified for each controller.
Also, all messages will be transmitted to the KEYBOARD PORT SET (p. 94) regardless of the
port that is specified for each controller.
fig.edt
1. Press the [EDIT] button.
The display will indicate “EDT”.
fig.omn
2. Press the [OMNI] key.
The display will blink “OMN”.
3. Confirm what’s indicated and press the [ENTER] button.
4. The display will show the current setting.
5. Use the [DEC] [INC] buttons or the [0] or [1] keys to select the mode.
6. Press the [ENTER] button.
0 OMNI OFF
Messages will be transmitted on the channel and port specified
for each controller.
1 OMNI ON
Messages will be transmitted on the current channel from the
Keyboard Port, regardless of the channel and port specified for
each controller.
Setting the input mode
fig.hexdec
If you are not in Play mode, you can use one of two ways to input a numerical
value into the PCR-1; Decimal input mode or Hexadecimal input mode.
If you want to input decimal numbers, press the [DECIMAL] button. If you
want to input hexadecimal numbers, press the [HEX] button. When you
connect the PCR-1 to your computer by USB cable, the PCR-1 will start up in
Decimal mode.
Decimal and hexadecimal numbers correspond as follows.
Decimal:0–127
Hexadecimal:00–7F
However, for MIDI CH and PROGRAM CHANGE, the values are as follows.
* Normally, the display will show three digits when using Decimal input mode. For this reason, there will
be no indication of the parameter you are now inputting, and you may lose track of what you are doing.
If this occurs, you can temporarily switch back to Hexadecimal mode to check the parameter you are
inputting. Then switch back to Decimal mode and continue.
Decimal Hexadecimal
MIDI CH 1–16 00–0F
PROGRAM CHANGE 1–128 00-7F