– 21 –
15. Trouble shooting
16. Technical Data
Signal change has no effect on the actuator position.
Check indicator and screw.
Check air supply to positioner and tubing to the
actuator.
Check input signal to positioner.
Check diaphragm for damage or leakage.
Check pilot valve function.
Check cam for correct setting.
Check I/P output
Note: All PMV-positioners are serialized. Please note
down, and provide the serial number when contacting
the factory for trouble shooting or service.
Signal change results in actuator running to end positions.
Check coupling between positioner and actuator.
Check cam position and locking screw.
Check input signal.
Inaccurate positioning.
Dirty or worn pilot valve.
Defective or leaking diaphragm.
Input signal fluctuates.
Incorrect sizing of actuator.
Valve/actuator "stiction".
High valve/actuator breakaway torque.
Loose cam.
P5 EP5
Input Signal 20-100 kPa/3-15 Psi (6-30 optional) 4-20 mA
Linearity 0,5%* 0,5%*
Hysteresis 0,75%* 0,5%*
Repeatability 0,5%* 0,5%*
Gain (pressure 600 kPa/87 Psi) 1 000 (kPa/kPa)
Min 66%/% ISA S75.13
Air consumption at Supply pressure:
0,2 MPa/29 Psi 5,4 nl/min 0.19 SCFM 6,1 nl/min 0.22 SCFM
0,4 MPa/58 Psi 12,3 nl/min 0.43 SCFM 13,6 nl/min 0.48 SCFM
0,6 MPa/87 Psi 20 nl/min 0.71 SCFM 22 nl/min 0.78 SCFM
0,8 MPa/116 Psi 27,8 nl/min 0.98 SCFM 30,5 nl/min 1.08 SCFM
1 MPa/145 Psi 35,7 nl/min 1.26 SCFM 39 nl/min 1.38 SCFM
Air delivery at Supply Pressure:
0,2 MPa/29 Psi 200 nl/min 6.9 SCFM
0,4 MPa/58 Psi 370 nl/min 12.8 SCFM
0,6 MPa/87 Psi 540 nl/min 18.8 SCFM
0,8 MPa/116 Psi 710 nl/min 24.7 SCFM
1 MPa/145 Psi 880 nl/min 30.6 SCFM
Supply Pressure Max 1 MPa/150 Psi 0,15-1 MPa/21,8-150 Psi
Temperature range -20°C to +85°C (-4°F to 185°F)
Connector threads 1/4" NPT or G
Gauge threads 1/8" NPT or G
Weight std. 1,1 kg/2.4 lbs 1,5 kg/3.4 lbs
Weight with gauges 1,3 kg/2.9 lbs 1,8 kg/3.9 lbs
Ingress protection IP 66/NEMA 4
* Per cent of full scale.
(The information in this manual is subject to change without notice.)