Roland XP-60 Operations Instructions Page 197

  • Download
  • Add to my manuals
  • Print
  • Page
    / 226
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 196
Omni On (Controller number 125)
status 2nd byte 3rd byte
BnH 7DH 00H
n=MIDI channel number : 0H - FH (ch.1 - ch.16)
* The same processing as when All Note Off is received will be done. The
instrument will not be set to OMNI ON.
* Not received in Performance mode if Rx Switch parameter (PERFORM/
MIDI/Part MIDI) is OFF.
Mono (Controller number 126)
status 2nd byte 3rd byte
BnH 7EH mmH
n=MIDI channel number : 0H - FH (ch.1 - ch.16)
mm=Mono number : 00H - 10H (0 - 16)
* The same processing as when All Note Off is received will be done, and the
Key Assign parameter (PATCH/Common/Common Control) will be set to
SOLO.
* Not received in Performance mode if Rx Switch parameter (PERFORM/
MIDI/Part MIDI) is OFF.
Poly (Controller number 127)
status 2nd byte 3rd byte
BnH 7FH 00H
n=MIDI channel number : 0H - FH (ch.1 - ch.16)
* The same processing as when All Note Off is received will be done, and the
Key Assign parameter (PATCH/Common/Common Control) will be set to
POLY.
* Not received in Performance mode if Rx Switch parameter (PERFORM/
MIDI/Part MIDI) is OFF.
System Realtime messages
Active Sensing
status
FEH
* When an Active Sensing message is received, the unit will begin monitoring
the interval at which MIDI messages are received. During monitoring, if
more than 420 ms passes without a message being received, the same
processing will be done as when All Sound Off, All Note Off, and Reset All
Controllers messages are received. Then monitoring will be halted.
System Exclusive messages
status data byte status
F0H iiH, ddH, ......, eeH F7H
F0H : System Exclusive message status
ii = ID number : This is the ID number (manufacturer ID) that spe-
cifies the manufacturer whose exclusive message
this is. Roland’s manufacturer ID is 41H.ID num-
bers 7EH and 7FH are defined in an expansion
of the MIDI standard as Universal Non-realtime
messages (7EH) and Universal Realtime
Messages (7FH).
dd,..., ee = data : 00H - 7FH (0 - 127)
F7H : EOX (End Of Exclusive)
Of the System Exclusive messages received by this device, the data of messa-
ges related to Mode settings and the Data Request (RQ1) messages will be set
automatically.
System Exclusive messages related to Mode settings
These messages are used to initialize the instrument to GM mode, or to switch
from one mode to another mode.
“GM System On” and “GM System Off” use Universal Non-realtime message
format.
GM System On
“GM System On” is a command message that resets the internal settings of
the instrument to the GM initial state (General MIDI System - Level 1). A GM
instrument that receives this message will automatically enter a state in which
it can correctly perform a GM score.
status
data byte status
F0H 7EH, 7FH, 09H, 01H F7H
Byte
Remarks
F0H Exclusive status
7EH ID number (Universal Non-realtime message)
7FH device ID (Broadcast)
09H sub ID#1 (General MIDI Message)
01H sub ID#2 (General MIDI On)
F7H EOX (End Of Exclusive)
* Not received when the Rx.GM-ON Message parameter (SYSTEM/MIDI/
MIDI Param 1) is OFF.
GM System Off
When this messages is received, this instrument will return to the performan-
ce mode.
status
data byte status
F0H 7EH, 7FH, 09H, 02H F7H
Byte
Remarks
F0H Exclusive status
7EH ID number (Universal Non-realtime message)
7FH device ID (Broadcast)
09H sub ID#1 (General MIDI Message)
02H sub ID#2 (General MIDI Off)
F7H EOX (End Of Exclusive)
* Not received when the Rx.GM-ON Message parameter (SYSTEM/MIDI/
MIDI Param 1) is OFF.
Data transmission
This instrument can use exclusive messages to exchange many varieties of
internal settings with other devices.
The model ID of the exclusive messages used by this instrument is 6AH.
Data Request 1 RQ1
This message requests the other device to transmit data. The address and size
indicate the type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it
is able to transmit data, and if the address and size are appropriate, the
requested data is transmitted as a Data Set 1 (DT1) message. If the conditions
are not met, nothing is transmitted.
status
data byte status
F0H
41H, dev, 6AH, 11H, aaH, bbH, ccH, ddH, ssH, ttH, uuH, vvH, sum
F7H
Byte
Remarks
F0H Exclusive status
41H ID number (Roland)
dev device ID (dev : 10H - 1FH)
6AH model ID (XP-60/XP-80)
11H command ID (RQ1)
aaH address MSB
bbH address
ccH address
ddH address LSB
ssH size MSB
ttH size
uuH size
vvH size LSB
sum checksum
F7H EOX (End Of Exclusive)
* The size of data that can be transmitted at one time is fixed for each type of
data. and data requests must be made with a fixed starting address and
size. Refer to the address and size given in “5. Parameter address map.”
(p.221)
* For the checksum, refer to page 227.
* This message is not received if the Rx.Sys.Excl parameter
(SYSTEM/MIDI/MIDI Param 1) is OFF.
* This message is not received in GM mode.
Data Set 1 DT1
This message transmits the actual data, and is used when you wish to set the
data of the receiving device.
status
data byte status
F0H
41H, dev, 6AH, 12H, aaH, bbH, ccH, ddH, eeH, ... ffH, sum
F7H
217
Capítulo 12. Material suplementario
Page view 196
1 2 ... 192 193 194 195 196 197 198 199 200 201 202 ... 225 226

Comments to this Manuals

No comments

MGE UPS Systems 30A manuels

Manuels d'utilisation et guides de l'utilisateur pour Unités d'alimentation électrique MGE UPS Systems 30A.
Nous fournissons des manuels en pdf 2 MGE UPS Systems 30A à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Unités d'alimentation électrique MGE UPS Systems

Modèles Type de document
6 kVA Manuel de l'utilisateur   5/7/11 kVA, 4 pages
40-75KVA Manuel de l'utilisateur   MGE Galaxy ® 3000 [en] , 62 pages
EPS 7000 Manuel de l'utilisateur   MGE EPS 7000 and MGE EPS 8000, 44 pages
EX40 Manuel de l'utilisateur   Total peace of mind with Pulsar services, 12 pages
FlexPDU 6 UNI Manuel de l'utilisateur   UPS & Power Quality Products, 32 pages
4 Manuel de l'utilisateur   MGE UPS Systems 4 User manual, 28 pages
Comet EX 7 RT 3:1 Manuel de l'utilisateur   MGE UPS SYSTEMS, 7 pages
Pulsar EX 700 Manuel de l'utilisateur   MGE UPS Systems Pulsar EX 700 User manual, 28 pages
2000 Manuel de l'utilisateur    MGE UPS Systems 2000 User manual, 64 pages
FlexPDU 6 AUS Manuel de l'utilisateur   Eaton 5130 UPS - A-TRAC, 8 pages
2200C Manuel de l'utilisateur    MGE UPS Systems 2200C User manual, 57 pages
1500 Manuel de l'utilisateur    MGE UPS Systems 1500 User manual, 65 pages
14+ Guide d'installation   MGE UPS Systems 14+ Installation guide, 203 pages
3200RT Manuel d'installation   MGE UPS Systems 3200RT Installation manual, 4 pages
14+ Manuel   MGE UPS Systems 14+ Hardware manual [en] , 276 pages
2000 Manuel de l'utilisateur   MGE UPS Systems 2000 User manual, 34 pages
12 kVA Manuel de l'utilisateur   MGE UPS Systems 12 kVA User manual, 32 pages
14+ Manuel de l'utilisateur     MGE UPS Systems 14+ User manual, 44 pages
AmpMeter PDU Manuel de l'utilisateur   Ampmeter PDU - NTC - Notstrom-Technik, 2 pages