Roland VS-1824 Owner's Manual Page 98

  • Download
  • Add to my manuals
  • Print
  • Page
    / 140
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 97
98
MIDI Implementation
aaH Response
::
bbH Response
F7H EOX (End of System Exclusive Message)
(*) see “3. MIDI Machine Control” section
Data Transfer (RQ1, DT1)
Data Request (RQ1)
Status Data Bytes Status
F0H 41H,Dev,00H,0EH,11H, F7H
aaH,bbH,ccH,ssH,ssH,ssH,Sum
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
Dev Device ID
mmH mmH Model ID (VS-1880/VS-1680)
11H Command ID (RQ1)
aaH Address MSB
bbH Address
ccH Address LSB
ssH Size MSB
ssH Size
ssH Size LSB
Sum Check Sum
F7H EOX (End of System Exclusive Message)
The message is used to request data to the VS-1824.
The VS-1824 does not transmit this message.
The VS-1824 transmits the requested data using Data Set(DT1) under following condition
when it received the message.
1. The requested address correspond to the specified parameter base address of
the VS-1824.
2. The requested size is over 1 byte.
Data Set (DT1)
Status Data Bytes Status
F0H 41H,Dev,00H,0EH,12H, F7H
aaH,bbH,ccH,ddH, ..., eeH,Sum
Byte Description
F0H Status of System Exclusive Message
41H Manufacturer ID (Roland)
Dev Device ID
mmH mmH Model ID (VS-1880/VS-1680)
12H Command ID (DT1)
aaH Address MSB
bbH Address
ccH Address LSB
ddH Data
::
eeH Data
Sum Check Sum
F7H EOX (End of System Exclusive Message)
The message is received under the following condition.
If the device ID on the message is same as that of the receive device, and the address on the
message correspond to the specified parameter base address, the received data are stored
from the specified parameter base address.
If the interval of received messages is shorter than 25 msec, the VS-1824 can not work the
receive message procedure correctly.
The message is transmitted under the following condition.
When the VS-1824 transmit the data on the requested parameter after receiving the Data
Request message (RQ1).
(*) see “2. Data Transfer Address Map” for more details of the transfer parameters.
The message is transmitted under the following condition.
When the VS-1824 transmit the data on the requested parameter after receiving the Data
Request message (RQ1).
(*) see “2. Data Transfer Address Map” for more details of the transfer parameters.
2. Data Transfer Address Map
Address are expressed in 7 - bit hexadecimal values.
+————————————————————————————————————————————————————————————————————————+
| Address | MSB | | LSB |
|——————————————————+—————————————————+—————————————————+—————————————————+
| Binary | 0aaa aaaa | 0bbb bbbb | 0ccc cccc |
| 7 Bit Hex | AA | BB | CC |
+————————————————————————————————————————————————————————————————————————+
Parameter Address Block
<Model ID = 00H 2AH>
+————————————————————————————————————————————————————————————————————————+
| Start | |
| address | Contents and remarks |
|==========+=============================================================|
| 00 00 00 | System Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 01 00 00 | Song Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 02 00 00 | Mixer Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 03 00 00 | Locate Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 04 00 00 | Effect Parameter |
|——————————+—————————————————————————————————————————————————————————————|
| 05 00 00 | Remote Operation |
|——————————+—————————————————————————————————————————————————————————————|
| 06 00 00 | (Reserved) |
| 07 00 00 | |
|——————————+—————————————————————————————————————————————————————————————|
| 08 00 00 | Sync Track Data |
| 09 00 00 | |
| 0A 00 00 | |
| 0B 00 00 | |
| 0C 00 00 | |
| 0D 00 00 | |
| 0E 00 00 | |
| 0F 00 00 | |
|——————————+—————————————————————————————————————————————————————————————|
| 10 00 00 | (Reserved) |
: :
| 7F 7F 7F | |
+————————————————————————————————————————————————————————————————————————+
System Parameter
+————————————————————————————————————————————————————————————————————————+
| Start | | |
| address | Data | Contents and remarks |
|==========+=========+===================================================|
| 00 00 00 | 0aaaaaaa| SMPTE(MTC) Offset Time |
| 00 00 01#| 0bbbbbbb| aaaaaaabbbbbbbcccccccddddddd = |
| 00 00 02#| 0ccccccc| 0,,,268435455block (1block=16sample) |
| 00 00 03#| 0ddddddd| |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 04 | 0aaaaaaa| Vari Pitch |
| 00 00 05#| 0bbbbbbb| 48kHz -241,,,23 (22.00,,,50.48kHz) |
| 00 00 06#| 0ccccccc| 44.1kHz -202,,,58 (22.05,,,50.43kHz) |
| 00 00 07#| 0ddddddd| 32kHz -93,,,172 (22.05,,,50.41kHz) |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 08 | 0aaaaaaa| (Reserved) |
| 00 00 09#| 0bbbbbbb| |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 0A | 00 - 01 | Vari Pitch Switch Off,On |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 0B | 00 - 01 | Marker Stop Switch Off,On |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 0C | 00 - 05 | Fade Length 2,10,20,30,40,50mS |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 0D | 0A - 64 | Preview From Length 1.0,,,10.0S |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 0E | 0A - 64 | Preview To Length 1.0,,,10.0S |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 0F | 00 - 05 | Foot Switch Assign Play/Stop,Record, |
| | | TapMarker,Next,Previous |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 10 | 00 - 02 | Metronome Out Mode Off,INT,MIDI |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 11 | 00 - 01 | Metronome Out Type REConly,AnyTime |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 12 | 00 - 02 | Master Clock DIGITAL1,INT,DIGITAL2 |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 13 | 00 - 1F | MIDI System Exclusive Device ID (*1) 1,,,32 |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 14 | 00 - 01 | MIDI OUT/THRU Switch (*1) Out,Thru |
|——————————+—————————+———————————————————————————————————————————————————|
| 00 00 15 | 00 - 01 | MIDI System Exclusive RX Switch (*1) Off,On |