Page view 121
120
Chapter 7 - Appendix
7-5 About Blade Life
Cutting conditions and blade life vary according to the hardness of the media and the usage environment. Making the
settings for the conditions described below does not automatically guarantee attractive cutting results in all situations.
Before performing actual cutting, be sure to carry out a cutting test and make any necessary adjustments (see "2-5
Cutting -- Test Cutting").
If the media is not cut through completely even when the tool force is increased by 50 to 60 gf more than the tool force
values shown below, it means that the useful life of the blade has ended. Replace with a new blade.
* The values for lifespan are intended to serve as a general guide when cutting media of identical type.
Blade
ZEC-U1005
ZEC-U5025
Media
General Signage Vinyl
General Signage Vinyl
Fluorescent Vinyl
Reflective Vinyl
Tool-force
50 to 150 gf
30 to 100 gf
120 to 200 gf
100 to 200 gf
Amount of cutter offset
0.25 mm (0.01 in.)
0.25 mm (0.01 in.)
0.25 mm (0.01 in.)
0.25 mm (0.01 in.)
Life of a blade
(General guide)
8000 m
4000 m
4000 m
4000 m