Roland FP-2 Owner's Manual Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
48
Chapter 4 Other Functions
1.
Switch to Function mode (p. 38), and press the
[Rec] button.
2.
Hold down the [Rec] button, and press the [-] or
[+] button so “L.Ct” is displayed.
fig.04-15
3.
Press the [-] or [+] button to switch Local Control
on and off.
Setting the MIDI Out Mode
By setting the MIDI Out Mode, you can select to have a more
suitable (to the external MIDI device) selection of MIDI data
be output from the MIDI Out connector when you make tone
changes on the FP-2.
Four settings for the MIDI Out Mode are available.
“MIDI Out Mode 1” is the power-up default setting.
1.
Switch to Function mode (p. 38), and press the
[Rec] button.
2.
Hold down the [Rec] button, and press the [-] or
[+] button so “OUt” is displayed.
fig.04-17
3.
Press the [-] or [+] button to select the MIDI Out
Mode.
Transferring the Program Change
Message
When a setup is switched, a Program Change message is
transmitted.
1.
Use a MIDI cable (optional) to connect the FP-2’s
MIDI OUT connector to the MIDI IN connector
on an external sequencer, or use a USB cable to
connect the computer.
2.
Switch to Function mode, and press the [Sound
Control] button.
3.
Hold down the [Sound Control] button, and press
the [-] or [+] button to select bank select MSB,
LSB or Program change (PC).
fig.disp—-
4.
Press [-] or [+] button to select the number.
5.
Exit Function mode to register the setup to the
settings (p. 33).
Using the Pedal to Switch Setup
(Pedal shift)
You can use the pedal which is connected to the
sostenuto(FC1) jack or the soft(FC2) jack as a dedicated
switch for selecting Setup in order.
1.
Switch to Function mode (p. 38), and press the
[Sound Control] button.
2.
Hold down the [Sound Control] button, and press
the [-] or [+] button so “SFt” is displayed.
Indication
Descriptions
1
MIDI Out Mode 1
This setting is suitable for the connection of
sequencers. The MIDI information (for exam-
ple: Bank select, Program Change, Settings of
Effects, and so on) is output from the MIDI
Out connector when you make a tone change
on the FP-2.
2
MIDI Out Mode 2
This setting is suited for connecting to a sound
module.
The MIDI information (for example:
Program change) is not output from the MIDI
Out connector when you make a tone change
on the FP-2.
3
MIDI Out Mode 3
You can transmit performance data recorded
with the FP-2.
Additionally, the MIDI messages that are out-
put have the same content as those in MIDI
Out Mode 1.
4
MIDI Out Mode 4
The MIDI messages that are output have the
same content as those in MIDI Out Mode 3.
However, these are not transmit to FP-2’s
sound module.
Additionally, the local control is switched to
off (p. 47).
Press
While holdin
g
down...
Press
While holding
down...
Press
While holding
down...
FP-2_e.book 48 ページ 2004年11月26日 金曜日 午後4時25分
Page view 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 75 76

Comments to this Manuals

No comments