MIDI Implementation
Model: MC-307 (groovebox)
Date: Feb. 22, 2000
Version: 1.01
Symbol Description Range
n MIDI Channel 0H6H,9H (ch.1ch.7,ch.10)
vv Control value 00H7FH (0127)
kk Note Number 00H7FH (0127)
xx ON/OFF 00H3FH (063:OFF), 40H7FH (64127:ON)
1. Data reception (sound source section)
Channel voice messages
Note Off
status 2nd byte 3rd byte
8nH kkH vvH
9nH kkH 00H
* Not received when the Rx Switch paramete is OFF.
* Not received by the Rhythm Part when the Envelope Mode parameter is NO-SUS.
* If the Remote Keyboard Switch is ON, the message will have the same effect as when a
note is released on the MC-307s keyboard. This means that you can control the
arpeggiator and RPS from an external MIDI keyboard.
Note On
status 2nd byte 3rd byte
9nH kkH vvH
vv=Note On velocity:01H - 7FH (1 - 127)
* Not received when the Rx Switch paramete is OFF.
* If the Remote Keyboard Switch is ON, the message will have the same effect as when a
note is played on the MC-307s keyboard. This means that you can control the
arpeggiator and RPS from an external MIDI keyboard.
Polyphonic Aftertouch
status 2nd byte 3rd byte
AnH kkH vvH
* Not received when the Rx Switch parameter is OFF.
* The effect will apply according to the Aftertouch Control setting.
Control Change
* Not received when the Rx Switch parameter is OFF.
Bank Select (Controller number 0,32)
status 2nd byte 3rd byte
BnH 00H mmH
BnH 20H llH
mm,ll=Bank number:00 00H7F 7FH (bank.1bank.16384)
* Not received when the Rx Program Change Switch or Rx Bank Select Switch parameter
is OFF.
* The Patches corresponding to each Bank Select are as follows.
Bank Select | Program No | Group Patch No.
MSB | LSB | |
——————+—————+————————————+————————————————————————————————————————
81 | 0 | 001 - 128 | Preset A 001 - 128
81 | 1 | 001 - 128 | Preset B 001 - 128
81 | 2 | 001 - 128 | Preset C 001 - 128
81 | 3 | 001 - 128 | Preset D 001 - 128
83 | 0 | 001 - 128 | Preset E 001 - 128
83 | 1 | 001 - 128 | Preset F 001 - 128
83 | 2 | 001 - 128 | Preset G 001 - 032
——————+—————+————————————+————————————————————————————————————————
85 | 0 | 001 - 128 | User A 001 - 128
85 | 1 | 001 - 128 | User B 001 - 128
* The Rhythm set corresponding to each Bank Select are as follows.
Bank Select | Program No | Group Patch No.
MSB | LSB | |
——————+—————+————————————+————————————————————————————————————————
81 | 0 | 1 - 26 | Preset A 01 - 26
83 | 0 | 1 - 14 | Preset B 01 - 14
——————+—————+————————————+————————————————————————————————————————
85 | 0 | 1 - 20 | User A 01 - 20
Modulation (Controller number 1)
status 2nd byte 3rd byte
BnH 01H vvH
* The effect will apply according to the Modulation Control setting.
Portamento Time (Controller number 5)
status 2nd byte 3rd byte
BnH 05H vvH
* The Portamento Time parameter will change.
Data Entry (Controller number 6,38)
status 2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
mm,ll= the value of the parameter specified by RPN mm=MSB, ll=LSB
Volume (Controller number 7)
status 2nd byte 3rd byte
BnH 07H vvH
* Volume messages are used to adjust the volume balance of each part.
Panpot (Controller number 10)
status 2nd byte 3rd byte
BnH 0AH vvH
* Adjust the stereo location over 128 steps, where 0 is far left, 64 is center, and 127 is far
right.
Expression (Controller number 11)
status 2nd byte 3rd byte
BnH 0BH vvH
* Expression messages are used to adjust the volume of each part.
General purpose Controller1 (Controller number 16)
status 2nd byte 3rd byte
BnH 10H vvH
* The LFO1 Rate parameter will change.
General purpose Controller3 (Controller number 18)
status 2nd byte 3rd byte
BnH 12H vvH
* The LFO1 Pitch Depth parameter will change.
General purpose Controller4 (Controller number 19)
status 2nd byte 3rd byte
BnH 13H vvH
* The LFO1 Filter Depth parameter will change relatively.
Hold 1 (Controller number 64)
status 2nd byte 3rd byte
BnH 40H xxH
* If the Remote Keyboard Switch is ON, it will be possible to control the Hold function of
the arpeggiator.
Portamento (Controller number 65)
status 2nd byte 3rd byte
BnH 41H xxH
* The Portamento Switch Parameter will change.
Sostenuto (Controller number 66)
status 2nd byte 3rd byte
BnH 42H xxH
Soft (Controller number 67)
status 2nd byte 3rd byte
BnH 43H xxH
Hold 2 (Controller number 69)
status 2nd byte 3rd byte
BnH 45H xxH
Page view 193