Roland MC-307 Owner's Manual Page 74

  • Download
  • Add to my manuals
  • Print
  • Page
    / 216
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 73
74
Chapter 5 Creating Your Own Patterns and
Modifying Performance Data
Values
Changes existing data settings.
Procedure
1. Press the [PTN] button.
2. Using the [VALUE] dial or the [INC/DEC] buttons,
select the pattern for which you want to edit.
3. Press the [F3 (EDIT] button.
The PATTERN EDIT screen appears.
4. Press the [F3 (MICRO SCOPE)] button.
The MICROSCOPE screen appears.
5. Use the [CURSOR (up/down)] buttons to select the data
whose setting is to be modified.
6. Use the [CURSOR (left/right)] buttons to move the
cursor to a setting as shown below.
7. Change a value using the [VALUE] dial or the [INC/
DEC] buttons.
Inserting Musical Data
(Insert Event)
Specify the position at which you want to insert data and
select the type of data to add.
Procedure
1. Press the [PTN] button.
2. Using the [VALUE] dial or the [INC/DEC] buttons,
select the pattern for which you want to edit.
3. Press the [F3 (EDIT] button.
The PATTERN EDIT screen appears.
4. Press the [F3 (MICROSCOPE)] button.
The MICROSCOPE screen appears.
5. Pressing the [CURSOR (left/right)] buttons, position the
cursor at the measure, beat or clock.
6. Determine the insertion position using the [VALUE] dial
or the [INC/DEC] buttons.
7. Press the [F1 (INS)] button.
The screen for selecting the types of data to be inserted
appears.
Example1: R, 1 - 7 Part
Example2: MUTE CTRL part
8. Select the type of data using the [VALUE] dial or the
[INC/DEC] buttons.
* For the types of data you can enter, see “Setting Range” at the
end of this section.
9. Upon selection, press the [F4 (OK)] button.
* When you have selected SYS-EX (System Exclusive), the
following message appears. Using the same procedure as the
one for Change Event, enter hexadecimal numbers by pressing
the keyboard pad and [ENTER] button in turn.
Available Settings:
When the microscope is in the range from [R], [1] to [7]:
- NOTE: Note
- PC: Program Change
- CC: Control Change
- BEND: Pitch Bend
- P-AFT: Polyphonic Aftertouch
- C-AFT: Channel Aftertouch
- When the microscope is MUTE CTRL:
When the microscope is in the MUTE CTRL:
- SYS-EX: System exclusive
- TEMPO: Tempo change message
- MUTE: Mute message
Invoke the microscope screen.
Specify the position at which data is to be inserted.
Insert the data.
Page view 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 215 216

Comments to this Manuals

No comments