MaxMotion for Machines Appendix E-231
spindle motor. Please, contact us if your machine has a DC
spindle motor.
F. Remember to invoke the MaxMotion application before
turning on the MaxAmp unit. It is possible that the spindle
motor may turn on when you turn on the power to the
MaxAmp unit and if the MaxMotion software is not on. This
sudden turning on of the spindle motor may startle you.
G. Make sure and do not block the area around the MaxAmp
module. Blocking the airflow could cause over heating of the
unit and could contribute to the heat related failure inside the
MaxAmp module.
H. Connect the MaxAmp box to AC outlet that has a ground pin.
Two pin outlet is not recommended.
J. We have designed the logic so that the stepper motors will be
driven with reduced power anytime they are not executing a
job or the operator is not jogging the table. This will keep the
motors from building up heat. Also, the amplifiers will run
cool. The motors will always be engaged and will keep proper
position of the table.
K. It is always a good practice to connect all the cables and turn
on the PC computer before turning on the amplifier. The
MaxAmp units are equipped with a power on red light.
Additionally, the cooling fan should always be on when the
power is applied to the unit.
L. Be sure to read the manual and ask us for our latest
information as well as our “How To...” notes to learn the use
of MaxMotion quickly and easily.
M. The following MaxAmp boxes have been made available
so far:
New Hermes 810 - 3 proper amplifiers and one relay for
spindle motor for original 810 motors
New Hermes 3000 - 3 proper amplifiers and one relay for
spindle motor for original 3000 motors
New Hermes 1219 and Vanguard II - 3 proper amplifiers
and one relay for spindle motor for original motors
New Hermes 4000, 5000, and 6000 - 3 proper amplifiers
and one relay for spindle motor for original motors
Newing Hall tables with TLC controllers - 2 proper
amplifiers and 3 relays are provided. The amplifiers are
designed for Superior Electric M063-FD06, 2.9 amp motors.