MaxMotion for Machines Appendix E-237
in your computer. If you have a printer connected to the
parallel port, disconnect the printer cable, connect the ID key,
tighten the screws, and reconnect the printer cable to the other
side of the ID key.
D. Make sure and connect the MaxAmp unit per installation
instructions in procedure E1.
E. The unique interface cable from the MaxAmp unit to the
Newing Hall table will have a 25 pin connector at the end of
the cable. This will connect directly to the matching interface
connector in the back of the engraving machine.
F. Connect the 25 pin interface connector into the back of your
engraving table.
G. Turn the power on to the system in the proper manner. If you
try to turn the screw on the table to move either axis, you
should feel the resistance.
H. Since you are working with MaxAmp module, do not select
either old or new EC controllers in the selection of the
engraving machine for the output. You should select MaxAmp
Newing as the output device. This tells the software that you
are driving the Newing Hall engraving machine with our
driver module.
CAUTIONS
A. There are no limit switches exist on Newing Hall 100 to 400 series
of machines.
B. You should use our 10 key Controlpad implementation to jog the
tool to the starting point of a job. Next, you should NOT use the
SURFACE command to set the Z axis. Simply use Z down key to
actuate your selected solenoids. You may have selected either left or
right or both solenoids.
E5. Installation instructions for MaxAmp Driver box to Hermes
810
STEP ONE
A. Make sure you have at least two printer ports in your Windows
computer.
B. Make sure that your PC meets the minimum requirements