MaxMotion for Machines Chapter 3-47
left before getting to the actual starting point.
Y axis - Negative value if the initial offset is to move away
from the operator before getting to the actual starting point.
Y axis - Positive value if the initial offset is to move toward
the operator before getting to the actual starting point.
Z axis - Positive value and the initial offset move can only
be going down toward the material.
D. Machine with limit switches in all three axis
Examples are Dahlgren System 100 - 500Z, Most New
Hermes machines like 1219, 3000, 3000LT, 5000, 6000, etc.
The X, Y, and Z axis limit switch settings are required in the
section II of the Machine Setup. The ‘Home’ position is where
the limit switches will take the machine upon clicking ‘Home’
key in the ControlPad. The operator should to go to the
Section III of the Machine Setup and select the appropriate
starting position. (Quite often this is the upper left or lower
left of the allowable machining area.) Additionally, the
operator should be able to enter values for the starting offsets
from the start position if he is interested in starting from a
point other than the position that the limit switch brings the
machine to. The offset value for the Z axis will be grayed out
and will not be available to the operator for entering any
value.
Starting offsets are to be entered as follows:
X axis - Positive value if the initial offset is to move to the
right before getting to the actual starting point.
X axis - Negative value if the initial offset is to move to the
left before getting to the actual starting point.
Y axis - Negative value if the initial offset is to move away
from the operator before getting to the actual starting point.
Y axis - Positive value if the initial offset is to move toward
the operator before getting to the actual starting point.
Z axis - The value cannot be declared if the limit switch is
set in the section II. The Z axis will move up and actuate the
limit switch to get to the Z axis Home position. The
application will be responsible for inserting the Z axis
maximum stroke value in the Starting offset area for the Z