MaxMotion for Machines Chapter 9-155
sending automated output. The password ensures that the operator does
not manipulate Serialization Setup to output unauthorized marking in-
between. If he has a genuine problem like one frame not output
properly and wanting to repeat the same frame, he will have to call the
supervisor to set things right from Serialization Setup. The log file
mentioned above will be witness to this repeat output and can be
verified with the supervisor later.
To setup serialization, on the main dialog, you supply total lines and
select current line. Next you specify total fields in this line and select
current field. As you choose Type of the field, you are enabled to
supply relevant information for that Field Type, as explained above.
This way you set up each field of each line. You can 'Insert' a field at
current field selection. Also you can 'Delete' (Remove) as well as
'Reset' current field. Similarly you can 'Insert', 'Delete' or 'Reset' a line.
You can start defining new serialization by doing 'Reset Serial'.
Once you save the setup, and then again open serialization dialog, you
will notice that Numeric, Letters and Alphanumeric fields display
Current Value of the field, stating for how many frames it will remain
same. If no output has been sent after defining serialization, the
Current value will be same as Initial value, otherwise after every frame
of output, it will have incremented according to the field definition.
You can 'Move Back' the serialization (all its fields) by specified # of
frames. This means you move in the reverse direction of definition, in
other words, decrement instead of incrementing the field value. If one
of the frames, while outputting is messed up and you want to repeat it,
this is not possible in the normal course, since the automated serializa-
tion would have moved on to next frame. The way out is, 'Move Back'
(default) one frame from within the dialog. The Current Values of the
incrementing fields will confirm this by reverting to last frame values.
You can move forward if you wish, by 'Moving Back' negative # of
frames, though I do not foresee any practical use of this.
Even after serial output has started and current values of fields have
began incrementing, you can modify the field and the subsequent
output will be done accordingly. Only exception is the Initial Value.
Once you see the Current Value displayed, the Initial value is not
referred at all, so changing it will not make any difference. If you want